A robust multi-shot scan strategy for high-resolution diffusion weighted MRI enabled by multiplexed sensitivity-encoding (MUSE) N Chen, A Guidon, HC Chang, AW Song Neuroimage 72, 41-47, 2013 | 454 | 2013 |
Soft robotic manipulator for intraoperative MRI-guided transoral laser microsurgery G Fang, MCK Chow, JDL Ho, Z He, K Wang, TC Ng, JKH Tsoi, PL Chan, ... Science Robotics 6 (57), eabg5575, 2021 | 99 | 2021 |
POCS‐based reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE): a general algorithm for reducing motion‐related artifacts ML Chu, HC Chang, HW Chung, TK Truong, MR Bashir, N Chen Magnetic resonance in medicine 74 (5), 1336-1348, 2015 | 96 | 2015 |
Human brain diffusion tensor imaging at submillimeter isotropic resolution on a 3 Tesla clinical MRI scanner HC Chang, M Sundman, L Petit, S Guhaniyogi, ML Chu, C Petty, ... Neuroimage 118, 667-675, 2015 | 80 | 2015 |
Salivary glands: echo-planar versus PROPELLER Diffusion-weighted MR imaging for assessment of ADCs CJ Juan, HC Chang, CJ Hsueh, HS Liu, YC Huang, HW Chung, CY Chen, ... Radiology 253 (1), 144-152, 2009 | 75 | 2009 |
Motion immune diffusion imaging using augmented MUSE for high‐resolution multi‐shot EPI S Guhaniyogi, ML Chu, HC Chang, AW Song, N Chen Magnetic resonance in medicine 75 (2), 639-652, 2016 | 62 | 2016 |
3D-MB-MUSE: A robust 3D multi-slab, multi-band and multi-shot reconstruction approach for ultrahigh resolution diffusion MRI IP Bruce, HC Chang, C Petty, NK Chen, AW Song Neuroimage 159, 46-56, 2017 | 59 | 2017 |
High-performance continuous hydraulic motor for MR safe robotic teleoperation Z Dong, Z Guo, KH Lee, G Fang, WL Tang, HC Chang, DTM Chan, ... IEEE Robotics and Automation Letters 4 (2), 1964-1971, 2019 | 58 | 2019 |
Deep learning-based thigh muscle segmentation for reproducible fat fraction quantification using fat–water decomposition MRI J Ding, P Cao, HC Chang, Y Gao, SHS Chan, V Vardhanabhuti Insights into imaging 11, 1-11, 2020 | 51 | 2020 |
Interleaved diffusion‐weighted improved by adaptive partial‐Fourier and multiband multiplexed sensitivity‐encoding reconstruction HC Chang, S Guhaniyogi, N Chen Magnetic resonance in medicine 73 (5), 1872-1884, 2015 | 48 | 2015 |
Improved delineation of short cortical association fibers and gray/white matter boundary using whole-brain three-dimensional diffusion tensor imaging at submillimeter spatial … AW Song, HC Chang, C Petty, A Guidon, NK Chen Brain connectivity 4 (9), 636-640, 2014 | 45 | 2014 |
Design of a percutaneous MRI-guided needle robot with soft fluid-driven actuator Z He, Z Dong, G Fang, JDL Ho, CL Cheung, HC Chang, CCN Chong, ... IEEE Robotics and Automation Letters 5 (2), 2100-2107, 2020 | 42 | 2020 |
Effects of gender, age, and body mass index on fat contents and apparent diffusion coefficients in healthy parotid glands: an MRI evaluation HC Chang, CJ Juan, HC Chiu, CC Cheng, SC Chiu, YJ Liu, HW Chung, ... European radiology 24, 2069-2076, 2014 | 40 | 2014 |
Comparison of acoustic radiation force impulse imaging derived carotid plaque stiffness with spatially registered MRI determined composition JR Doherty, JJ Dahl, PG Kranz, N El Husseini, HC Chang, N Chen, ... IEEE transactions on medical imaging 34 (11), 2354-2365, 2015 | 38 | 2015 |
Susceptibility-weighted imaging in patients with pyogenic brain abscesses at 1.5 T: characteristics of the abscess capsule PH Lai, HC Chang, TC Chuang, HW Chung, JY Li, MJ Weng, JH Fu, ... American journal of neuroradiology 33 (5), 910-914, 2012 | 38 | 2012 |
Shape tracking and feedback control of cardiac catheter using MRI-guided robotic platform—Validation with pulmonary vein isolation simulator in MRI Z Dong, X Wang, G Fang, Z He, JDL Ho, CL Cheung, WL Tang, X Xie, ... IEEE Transactions on Robotics 38 (5), 2781-2798, 2022 | 35 | 2022 |
Susceptibility-weighted imaging provides complementary value to diffusion-weighted imaging in the differentiation between pyogenic brain abscesses, necrotic glioblastomas, and … PH Lai, HW Chung, HC Chang, JH Fu, PC Wang, SH Hsu, SS Hsu, ... European Journal of Radiology 117, 56-61, 2019 | 32 | 2019 |
Phase correction for three‐dimensional (3D) diffusion‐weighted interleaved EPI using 3D multiplexed sensitivity encoding and reconstruction (3D‐MUSER) HC Chang, ES Hui, PW Chiu, X Liu, N Chen Magnetic resonance in medicine 79 (5), 2702-2712, 2018 | 32 | 2018 |
B-value optimization in the estimation of intravoxel incoherent motion parameters in patients with cervical cancer JAU Perucho, HCC Chang, V Vardhanabhuti, M Wang, AS Becker, ... Korean journal of radiology 21 (2), 218-227, 2020 | 27 | 2020 |
Differential brainstem atrophy patterns in multiple sclerosis and neuromyelitis optica spectrum disorders CY Lee, HKF Mak, PW Chiu, HC Chang, F Barkhof, KH Chan Journal of Magnetic Resonance Imaging 47 (6), 1601-1609, 2018 | 24 | 2018 |