追蹤
Hing-Chiu Chang
Hing-Chiu Chang
Assistant Professor at The Chinese University of Hong Kong
在 ntu.edu.tw 的電子郵件地址已通過驗證
標題
引用次數
引用次數
年份
A robust multi-shot scan strategy for high-resolution diffusion weighted MRI enabled by multiplexed sensitivity-encoding (MUSE)
N Chen, A Guidon, HC Chang, AW Song
Neuroimage 72, 41-47, 2013
4542013
Soft robotic manipulator for intraoperative MRI-guided transoral laser microsurgery
G Fang, MCK Chow, JDL Ho, Z He, K Wang, TC Ng, JKH Tsoi, PL Chan, ...
Science Robotics 6 (57), eabg5575, 2021
992021
POCS‐based reconstruction of multiplexed sensitivity encoded MRI (POCSMUSE): a general algorithm for reducing motion‐related artifacts
ML Chu, HC Chang, HW Chung, TK Truong, MR Bashir, N Chen
Magnetic resonance in medicine 74 (5), 1336-1348, 2015
962015
Human brain diffusion tensor imaging at submillimeter isotropic resolution on a 3 Tesla clinical MRI scanner
HC Chang, M Sundman, L Petit, S Guhaniyogi, ML Chu, C Petty, ...
Neuroimage 118, 667-675, 2015
802015
Salivary glands: echo-planar versus PROPELLER Diffusion-weighted MR imaging for assessment of ADCs
CJ Juan, HC Chang, CJ Hsueh, HS Liu, YC Huang, HW Chung, CY Chen, ...
Radiology 253 (1), 144-152, 2009
752009
Motion immune diffusion imaging using augmented MUSE for high‐resolution multi‐shot EPI
S Guhaniyogi, ML Chu, HC Chang, AW Song, N Chen
Magnetic resonance in medicine 75 (2), 639-652, 2016
622016
3D-MB-MUSE: A robust 3D multi-slab, multi-band and multi-shot reconstruction approach for ultrahigh resolution diffusion MRI
IP Bruce, HC Chang, C Petty, NK Chen, AW Song
Neuroimage 159, 46-56, 2017
592017
High-performance continuous hydraulic motor for MR safe robotic teleoperation
Z Dong, Z Guo, KH Lee, G Fang, WL Tang, HC Chang, DTM Chan, ...
IEEE Robotics and Automation Letters 4 (2), 1964-1971, 2019
582019
Deep learning-based thigh muscle segmentation for reproducible fat fraction quantification using fat–water decomposition MRI
J Ding, P Cao, HC Chang, Y Gao, SHS Chan, V Vardhanabhuti
Insights into imaging 11, 1-11, 2020
512020
Interleaved diffusion‐weighted improved by adaptive partial‐Fourier and multiband multiplexed sensitivity‐encoding reconstruction
HC Chang, S Guhaniyogi, N Chen
Magnetic resonance in medicine 73 (5), 1872-1884, 2015
482015
Improved delineation of short cortical association fibers and gray/white matter boundary using whole-brain three-dimensional diffusion tensor imaging at submillimeter spatial …
AW Song, HC Chang, C Petty, A Guidon, NK Chen
Brain connectivity 4 (9), 636-640, 2014
452014
Design of a percutaneous MRI-guided needle robot with soft fluid-driven actuator
Z He, Z Dong, G Fang, JDL Ho, CL Cheung, HC Chang, CCN Chong, ...
IEEE Robotics and Automation Letters 5 (2), 2100-2107, 2020
422020
Effects of gender, age, and body mass index on fat contents and apparent diffusion coefficients in healthy parotid glands: an MRI evaluation
HC Chang, CJ Juan, HC Chiu, CC Cheng, SC Chiu, YJ Liu, HW Chung, ...
European radiology 24, 2069-2076, 2014
402014
Comparison of acoustic radiation force impulse imaging derived carotid plaque stiffness with spatially registered MRI determined composition
JR Doherty, JJ Dahl, PG Kranz, N El Husseini, HC Chang, N Chen, ...
IEEE transactions on medical imaging 34 (11), 2354-2365, 2015
382015
Susceptibility-weighted imaging in patients with pyogenic brain abscesses at 1.5 T: characteristics of the abscess capsule
PH Lai, HC Chang, TC Chuang, HW Chung, JY Li, MJ Weng, JH Fu, ...
American journal of neuroradiology 33 (5), 910-914, 2012
382012
Shape tracking and feedback control of cardiac catheter using MRI-guided robotic platform—Validation with pulmonary vein isolation simulator in MRI
Z Dong, X Wang, G Fang, Z He, JDL Ho, CL Cheung, WL Tang, X Xie, ...
IEEE Transactions on Robotics 38 (5), 2781-2798, 2022
352022
Susceptibility-weighted imaging provides complementary value to diffusion-weighted imaging in the differentiation between pyogenic brain abscesses, necrotic glioblastomas, and …
PH Lai, HW Chung, HC Chang, JH Fu, PC Wang, SH Hsu, SS Hsu, ...
European Journal of Radiology 117, 56-61, 2019
322019
Phase correction for three‐dimensional (3D) diffusion‐weighted interleaved EPI using 3D multiplexed sensitivity encoding and reconstruction (3D‐MUSER)
HC Chang, ES Hui, PW Chiu, X Liu, N Chen
Magnetic resonance in medicine 79 (5), 2702-2712, 2018
322018
B-value optimization in the estimation of intravoxel incoherent motion parameters in patients with cervical cancer
JAU Perucho, HCC Chang, V Vardhanabhuti, M Wang, AS Becker, ...
Korean journal of radiology 21 (2), 218-227, 2020
272020
Differential brainstem atrophy patterns in multiple sclerosis and neuromyelitis optica spectrum disorders
CY Lee, HKF Mak, PW Chiu, HC Chang, F Barkhof, KH Chan
Journal of Magnetic Resonance Imaging 47 (6), 1601-1609, 2018
242018
系統目前無法執行作業,請稍後再試。
文章 1–20